dc.description.abstractThe distribution of fluorescence signals measured with flow cytometry can be influenced by several factors, including qualitative and quantitative properties of the used fluorochromes, optical properties of the detection system, as well as the variability within the analyzed cell population itself. Most of the single cell samples prepared from in vitrocultures or clinical specimens contain a variable cell cycle component. Cell cycle, together with changes in the cell size, are two of the factors that alter the functional properties of analyzed cells and thus affect the interpretation of obtained results. Here, we describe the association between cell cycle status and cell size, and the variability in the distribution of fluorescence intensity as determined with flow cytometry, at population scale. We show that variability in the distribution of background and specific fluorescence signals is related to the cell cycle state of the selected population, with the 10% low fluorescence signal fraction enriched mainly in cells in their G0/G1 cell cycle phase, and the 10% high fraction containing cells mostly in the G2/M phase. Therefore we advise using caution and additional experimental validation when comparing populations defined by fractions at both ends of fluorescence signal distribution to avoid biases caused by the effect of cell cycle and cell size.en
dc.language.isoen
dc.relation.urlhttps://doi.org/10.1038/s41598-023-31990-1
dc.rightsCreative Commons Uveďte původ 4.0 Internationalcs
dc.rightsCreative Commons Attribution 4.0 Internationalen
dc.titleVariability of fluorescence intensity distribution measured by flow cytometry is influenced by cell size and cell cycle progressionen
dcterms.accessRightsopenAccess
dcterms.licensehttps://creativecommons.org/licenses/by/4.0/legalcode
dc.date.updated2023-12-04T11:10:38Z
dc.subject.keywordfluorescence intensity distributionen
dc.subject.keywordflow cytometryen
dc.subject.keywordcell sizeen
dc.subject.keywordcell cycle progressionen
dc.relation.fundingReferenceinfo:eu-repo/grantAgreement/MZ0/NV/NV18-08-00245
dc.relation.fundingReferenceinfo:eu-repo/grantAgreement/MZ0/NU/NU20J-07-00028
dc.relation.fundingReferenceinfo:eu-repo/grantAgreement/MSM//LX22NPO5102
dc.relation.fundingReferenceinfo:eu-repo/grantAgreement/FN/I-FN/I-FNM
dc.date.embargoStartDate2023-12-04
dc.type.obd73
dc.type.versioninfo:eu-repo/semantics/publishedVersion
dc.identifier.doi10.1038/s41598-023-31990-1
dc.identifier.utWos001017313600005
dc.identifier.eidScopus2-s2.0-85150947560
dc.identifier.obd625974
dc.identifier.pubmed36966193
dc.subject.rivPrimary30000::30200::30205
dc.subject.rivSecondary30000::30200::30204
dcterms.isPartOf.nameScientific Reports
dcterms.isPartOf.issn2045-2322
dcterms.isPartOf.journalYear2023
dcterms.isPartOf.journalVolume13
dcterms.isPartOf.journalIssue1
uk.faculty.primaryId109
uk.faculty.primaryName2. lékařská fakultacs
uk.faculty.primaryNameSecond Faculty of Medicineen
uk.faculty.secondaryId52
uk.faculty.secondaryNameFakultní nemocnice v Motolecs
uk.faculty.secondaryNameMotol University Hospitalen
uk.department.primaryId109
uk.department.primaryName2. lékařská fakultacs
uk.department.primaryNameSecond Faculty of Medicineen
uk.department.secondaryId1675
uk.department.secondaryId100010692507
uk.department.secondaryNameKlinika dětské hematologie a onkologiecs
uk.department.secondaryNameKlinika dětské hematologie a onkologieen
uk.department.secondaryNameKlinika dětské hematologie a onkologie 2. LF UK a FN Motolcs
uk.department.secondaryNameDepartment of Paediatric Haematology and Oncology, 2nd Faculty of Medicine and Motol University Hosen
dc.type.obdHierarchyCsČLÁNEK V ČASOPISU::článek v časopisu::původní článekcs
dc.type.obdHierarchyEnJOURNAL ARTICLE::journal article::original articleen
dc.type.obdHierarchyCode73::152::206en
uk.displayTitleVariability of fluorescence intensity distribution measured by flow cytometry is influenced by cell size and cell cycle progressionen


Soubory tohoto záznamu

Thumbnail

Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam