Zobrazit minimální záznam

Left ventricular septal pacing - can we trust the ECG?

dc.contributor.authorČurila, Karol
dc.contributor.authorBurri, Haran
dc.date.accessioned2023-12-29T12:10:39Z
dc.date.available2023-12-29T12:10:39Z
dc.date.issued2023
dc.identifier.urihttps://hdl.handle.net/20.500.14178/2160
dc.description.abstractIn contrast to left bundle branch pacing, the criteria for left ventricular septal pacing (LVSP) were never validated. LVSP is usually defined as deep septal deployment of the pacing lead with a pseudo-right bundle branch morphology in V1. The case report describes an implant procedure during which this definition of LVSP was fulfilled in four of five pacing locations within the septum, with the shallowest of them present in less than 50% of the septal thickness. The case highlights the need for a more precise definition of LVSP.en
dc.language.isoen
dc.relation.urlhttps://doi.org/10.1016/j.ipej.2023.07.001
dc.rightsCreative Commons Uveďte původ-Neužívejte dílo komerčně-Nezpracovávejte 4.0 Internationalcs
dc.rightsCreative Commons Attribution-NonCommercial-NoDerivativeWorks 4.0 Internationalen
dc.titleLeft ventricular septal pacing - can we trust the ECG?en
dcterms.accessRightsopenAccess
dcterms.licensehttps://creativecommons.org/licenses/by-nc-nd/4.0/legalcode
dc.date.updated2024-02-02T09:40:48Z
dc.subject.keywordleft ventricular septal pacingen
dc.subject.keywordimplant procedureen
dc.subject.keywordcriteriaen
dc.subject.keywordcase reporten
dc.relation.fundingReferenceinfo:eu-repo/grantAgreement/MSM//LX22NPO5104
dc.relation.fundingReferenceinfo:eu-repo/grantAgreement/UK/COOP/COOP
dc.date.embargoStartDate2024-02-02
dc.type.obd73
dc.type.versioninfo:eu-repo/semantics/publishedVersion
dc.identifier.doi10.1016/j.ipej.2023.07.001
dc.identifier.eidScopus2-s2.0-85166965803
dc.identifier.obd633394
dc.identifier.pubmed37429526
dc.subject.rivPrimary30000::30200::30201
dcterms.isPartOf.nameIndian Pacing and Electrophysiology Journal
dcterms.isPartOf.issn0972-6292
dcterms.isPartOf.journalYear2023
dcterms.isPartOf.journalVolume23
dcterms.isPartOf.journalIssue6
uk.faculty.primaryId110
uk.faculty.primaryName3. lékařská fakultacs
uk.faculty.primaryNameThird Faculty of Medicineen
uk.department.primaryId110
uk.department.primaryName3. lékařská fakultacs
uk.department.primaryNameThird Faculty of Medicineen
uk.department.secondaryId634
uk.department.secondaryNameKardiologická klinika 3. LF UK a FNKVcs
uk.department.secondaryNameDepartment of Cardiology 3FM CU and UHKVen
dc.description.pageRange155-157
dc.type.obdHierarchyCsČLÁNEK V ČASOPISU::článek v časopisu::kazuistikacs
dc.type.obdHierarchyEnJOURNAL ARTICLE::journal article::casuisticsen
dc.type.obdHierarchyCode73::152::202en
uk.displayTitleLeft ventricular septal pacing - can we trust the ECG?en


Soubory tohoto záznamu

Thumbnail

Tento záznam se objevuje v následujících kolekcích

Zobrazit minimální záznam