Optimization of quasi-hemispherical CdZnTe detectors by means of first principles simulation

původní článek
Creative Commons License IconCreative Commons BY Icon
en
vydavatelská verze
  • žádná další verze
Thumbnail
File can be accessed.Získat publikaci
Autor
Vicini, Valentina
Zanettini, Silvia
Sarzi Amade, Nicola
Grill, RomanORCiD Profile - 0000-0002-4615-8909WoS Profile - A-2109-2008Scopus Profile - 10039402900
Zambelli, Nicola
Calestani, Davide
Zappettini, Andrea
Abbene, Leonardo
Bettelli, Manuele

Zobrazit další autory

Datum vydání
2023
Publikováno v
Scientific Reports
Nakladatel / Místo vydání
NATURE PORTFOLIO
Ročník / Číslo vydání
13 (1)
ISBN / ISSN
ISSN: 2045-2322
ISBN / ISSN
eISSN: 2045-2322
Informace o financování
UK//COOP
GA0//GA19-11920S
Metadata
Zobrazit celý záznam
Kolekce
  • Matematicko-fyzikální fakulta

Tato publikace má vydavatelskou verzi s DOI 10.1038/s41598-023-30181-2

Abstrakt
In this paper we present the development of quasi-hemispherical gamma-ray detectors based on CdZnTe. Among the possible single-polarity electrode configurations, such as coplanar, pixelated, or virtual Frisch-grid geometries, quasi-hemispherical detectors are the most cost-effective alternative with comparable raw energy resolution in the high and low energy range. The optimal configuration of the sensor in terms of dimension of the crystals and electrode specifications has been first determined by simulations, and successively validated with experimental measures. Spectra from different sources have been acquired to evaluate the detectors performances. Three types of detectors with different CZT volumes have been fabricated, namely 10 x 10 x 5 mm(3), 15 x 15 x 10 mm(3) and 20 x 20 x 10 mm(3). In the case of 10 x 10 x 5 mm(3) crystals, the optimum pixel size determined by our simulation tool was confirmed by experiments: the best spectroscopic resolution of 1.3% at 662 keV has been found for a 750 µm diameter pixel detector. The best energy resolution values obtained for the 15 x 15 x 10 mm(3) and 20 x 20 x 10 mm(3) detectors were respectively 1.7% and 2.7% at 662 keV.
Klíčová slova
CdZnTe, detectors, simulation, spectroscopy
Trvalý odkaz
https://hdl.handle.net/20.500.14178/2359
Zobraz publikaci v dalších systémech
WOS:000942280900008
SCOPUS:2-s2.0-85148965519
PUBMED:36828862
Licence

Licence pro užití plného textu výsledku: Creative Commons Uveďte původ 4.0 International

Zobrazit podmínky licence

xmlui.dri2xhtml.METS-1.0.item-publication-version-

DSpace software copyright © 2002-2016  DuraSpace
Kontaktujte nás | Vyjádření názoru
Theme by 
Atmire NV
 

 

O repozitáři

O tomto repozitářiAkceptované druhy výsledkůPovinné popisné údajePoučeníCC licence

Procházet

Vše v DSpaceKomunity a kolekcePracovištěDle data publikováníAutořiNázvyKlíčová slovaTato kolekcePracovištěDle data publikováníAutořiNázvyKlíčová slova

DSpace software copyright © 2002-2016  DuraSpace
Kontaktujte nás | Vyjádření názoru
Theme by 
Atmire NV