Skip to main content

Research publications repository

    • čeština
    • English
  • English 
    • čeština
    • English
  • Login
View Item 
  •   CU Research Publications Repository
  • Fakulty
  • Faculty of Mathematics and Physics
  • View Item
  • CU Research Publications Repository
  • Fakulty
  • Faculty of Mathematics and Physics
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Optimization of quasi-hemispherical CdZnTe detectors by means of first principles simulation

original article
Creative Commons License IconCreative Commons BY Icon
en
published version
  • no other version
Thumbnail
File can be accessed.Get publication
Author
Vicini, Valentina
Zanettini, Silvia
Sarzi Amade, Nicola
Grill, RomanORCiD Profile - 0000-0002-4615-8909WoS Profile - A-2109-2008Scopus Profile - 10039402900
Zambelli, Nicola
Calestani, Davide
Zappettini, Andrea
Abbene, Leonardo
Bettelli, Manuele

Show other authors

Publication date
2023
Published in
Scientific Reports
Publisher / Publication place
NATURE PORTFOLIO
Volume / Issue
13 (1)
ISBN / ISSN
ISSN: 2045-2322
ISBN / ISSN
eISSN: 2045-2322
Funding Information
UK//COOP
GA0//GA19-11920S
Metadata
Show full item record
Collections
  • Faculty of Mathematics and Physics

This publication has a published version with DOI 10.1038/s41598-023-30181-2

Abstract
In this paper we present the development of quasi-hemispherical gamma-ray detectors based on CdZnTe. Among the possible single-polarity electrode configurations, such as coplanar, pixelated, or virtual Frisch-grid geometries, quasi-hemispherical detectors are the most cost-effective alternative with comparable raw energy resolution in the high and low energy range. The optimal configuration of the sensor in terms of dimension of the crystals and electrode specifications has been first determined by simulations, and successively validated with experimental measures. Spectra from different sources have been acquired to evaluate the detectors performances. Three types of detectors with different CZT volumes have been fabricated, namely 10 x 10 x 5 mm(3), 15 x 15 x 10 mm(3) and 20 x 20 x 10 mm(3). In the case of 10 x 10 x 5 mm(3) crystals, the optimum pixel size determined by our simulation tool was confirmed by experiments: the best spectroscopic resolution of 1.3% at 662 keV has been found for a 750 µm diameter pixel detector. The best energy resolution values obtained for the 15 x 15 x 10 mm(3) and 20 x 20 x 10 mm(3) detectors were respectively 1.7% and 2.7% at 662 keV.
Keywords
CdZnTe, detectors, simulation, spectroscopy
Permanent link
https://hdl.handle.net/20.500.14178/2359
Show publication in other systems
WOS:000942280900008
SCOPUS:2-s2.0-85148965519
PUBMED:36828862
License

Full text of this result is licensed under: Creative Commons Uveďte původ 4.0 International

Show license terms

xmlui.dri2xhtml.METS-1.0.item-publication-version-

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV
 

 

About Repository

About This RepositoryResearch outputs typologyRequired metadataDisclaimerCC Linceses

Browse

All of DSpaceCommunities & CollectionsWorkplacesBy Issue DateAuthorsTitlesSubjectsThis CollectionWorkplacesBy Issue DateAuthorsTitlesSubjects

DSpace software copyright © 2002-2016  DuraSpace
Contact Us | Send Feedback
Theme by 
Atmire NV